بیولوژی سلولی
Solarbio

Luminescent Cell Viability Assay Kit I Plus

توضیحات و پروتکل‌های فنی

1. Storage at -20°C will cause a gradual decline in this product's detection efficacy. After one year of storage,its luminescence will decrease by approximately 35%. Therefore,for more stable luminescence performance,we recommend storing this product at -80°C in the dark. Alternatively,consider purchasing the Luminescence-Based Cell Viability Assay Kit II Series,which maintains exceptional stability at -20°C. 2. The detection reagent in this kit contains luciferase,which may gradually inactivate with repeated freeze-thaw cycles. Although testing shows no significant impact on detection performance after 5 freeze-thaw cycles,for optimal results,aliquot the reagent after the first thaw. Ensure aliquoting containers are free from ATP contamination. During repeated freeze-thaw cycles,minor precipitation may occur in the assay reagent. In such cases,allow the reagent to equilibrate to room temperature and dissolve the precipitate as much as possible. If insoluble residue remains,centrifuge it off before use. Testing confirms this does not affect subsequent assay performance. 3. High solvent content in the drug under test may interfere with the luciferase reaction,thereby affecting the chemiluminescence signal. Solvent interference can be excluded by including a control well containing cell culture medium with the same solvent. Testing confirms that DMSO concentrations below 2% in the final reaction system do not affect the reaction. 4. Use white or black 96-well or 384-well plates for detection. Transparent plates may cause cross-interference between adjacent wells. 5. While the manual provides a method for testing ATP standards,actual cell viability assays typically do not require ATP standard testing. Product Description: Luminescent Cell Viability Assay Kit I Plus is a kit that uses chemiluminescence to measure intracellular ATP content,enabling ultra-high sensitivity and ultra-wide linear range quantitative detection of live cell numbers. This product is a ready-to-use liquid,offering the advantage of direct use without preparation. However,long-term storage requires storage at -80oC; prolonged storage at -20oC will gradually reduce the detection performance. Product Features: 1. This product has high detection sensitivity and a wide linear range,exhibiting a good linear relationship within the range of 12 to 100,000 cells. 2. This product is easy to use,provides stable readings,and offers fast detection,completing the assay in approximately 10 minutes. 3. This product has high luminescence intensity. 4. This product has good stability. The luminescence detection reagent in this kit has good stability; repeated freezing and thawing 5 times has virtually no effect on the detection results,and repeated freezing and thawing 10 times results in a decrease in detection performance of no more than 10%. 5. This product is flexible and convenient to use. This product is suitable not only for testing small sample sizes but also for high-throughput screening of large sample sizes. For cell numbers not exceeding 30,000,the I and II standard series can be selected; for cell numbers potentially exceeding 30,000,the Plus series is recommended; for applications requiring particularly high stability of detection data,the Steady series is recommended; and for long-term stable storage at -20℃,the lyophilized powder packaging of the II series is recommended.
مشخصات و اطلاعات آزمایشگاهی
کد کاتالوگ:
C-CA3711-500T
وضعیت تامین:
موجود در انبار سیترا بیوتک
Appearance:
liquid
Storage:
Store at -20℃ avoid light at least 1 year
تحویل:
یک ماه پس از سفارش
162000000
162000000 تومان